HomeOdor & Emission ControlProtection of Critical Electronics
Protection of Critical Electronics
We offer advanced PureAir filtration systems to protect critical electronic equipment from corrosive gases and environmental hazards. Our solutions prevent equipment failure and ensure the reliability of control rooms, data centers, and industrial electronics.
We specialize in protecting critical electronics
Protection of mission critical electronics hardware
Elimination of hydrogen sulfide and other corrosive emissions
These gases can cause whiskers and short-circuiting which can lead to production loss, plant interruptions, and accidents.
In commercial environments like data centers, we super-purify the air to protect valuable servers, thus protecting critical company data & processes.
We offer multiple models of air handling units, depending on requirements and needs. Each unit is customizable.
We also offer simplified, ready-to-go units, which are ready to ship upon purchase: PFU-Mobile and PFU-Mini. Other, larger PFU models are also available for higher airflow systems.
Our SAH unit is often used in applications requiring a more customized and robust system. Other options, including deep bed systems, are available as well.
Motor Control Center (MCC)
Distributed Control System (DCS)
Programmable Logic Controller (PLC)
Control Room and Panels
Rack Room
Card Failure
Corrosivity Test Kit
From left to right: G1, G2, G3, GX
ISA CLASSIFICATION
G1
G2
G3
GX
Mild (Acceptable)
Moderate
Harsh
Severe
Corrosion is not a factor
Corrosion is measurable
High probability that corrosion attacks will occur
Electronic/electrical equipment is not expected to survive
Copper Reactivity Level
0-299 Angstroms
300-999 Angstroms
1000-1999 Angstroms
≥ 2000 Angstroms
Silver Reactivity Level
0-199 Angstroms
200-999 Angstroms
1000-1999 Angstroms
≥ 2000 Angstroms
Contaminants
Concentration
H2S Hydrogen Sulfide
< 3 ppb
< 10 ppb
< 50 ppb
≥ 50 ppb
SO2 Sulfur Dioxide
< 10 ppb
< 100 ppb
< 300 ppb
≥ 300 ppb
CL2 Chlorine
< 1 ppb
< 2 ppb
< 10 ppb
≥ 10 ppb
NOx Nitrogen Oxides
< 50 ppb
< 125 ppb
< 1250 ppb
≥ 1250 ppb
NH3 Ammonia
< 500 ppb
< 10,000 ppb
< 25,000 ppb
≥ 25,000 ppb
O3 Ozone
< 2 ppb
< 25 ppb
< 100 ppb
≥ 100 ppb
HF Hydrogen Fluoride
< 1 ppb
< 2 ppb
< 10 ppb
> 10 ppb
PureAir's ECMv2:
Offers live, accurate results of environment surveillance and detection of corrosion.
This prevents expensive interruptions by saving valuable electronics.
Benefits:
Constant Environment Surveillance
Early Detection
Easy to Install
Long Service Life
Ethernet Connection
ISA Standards:
World Wide Standard for Protecting Industrial Electronics: ISA S71.04
G1 level needed to protect electronics, but many factors must also be reviewed: